Providing you the best range of Morley & Notifier -Honeywell Products
Notifier Fire Alarm Controller Supply
Notifier Smoke Detector System
Notifier Fire Alam Control Panel
Notifier Fire Alarm System
NOTIFIER FIRE ALARM SYSTEM
NOTIFIER FAS SUPPLIER OF HONEYWELL
NOTIFIER FIRE ALARM SYSTEM
NOTIFIER SMOKE DETECTORNOTIFIER FIRE ALARM SYSTEMNOTIFIER FIRE CONTROL SYSTEMNOTIFIER FIRE DETCTION SYSTEM NOTIFIER FIRE SCANNIGN SYSTEM NOTIFIER FIRE ALARM PANEL NOTIFIER FAS FIRE PANEL ADDRESSABLE NOTIFIER INTELLIGENT ADDRESSABLE NOTIFIER FIRE ALA NOTIFIER ADDRESSABLE FIRE ALARM PANEL NOTIFIER BY HONEYWELL NFS320 SINGLE LOOP FIRE PANELNOTIFIER F NFS640 LOOP2 FIRE ALARM CONTROL PANELHONEYWELL NOTIFIER F NFS3030 4 LOOP 6 LOOP 10 LOOP FIRE PANELNOTIFIER FIRE ALARM SYSTEM NOTIFIER PA AMPLIFIER DISTRIBUTOR NOTIFIER PAS SYSTEM SPEAKER AMPLIFIER WHOLESALER
PART NUMBER DESCRIPTION
“Select” Series Addressable Detectors and Base
FSP/951 Photo Notifier White
FSP/951T Photo/Thermal Notifier White
FST/951R Heat ROR Notifier White
FST/951H Heat High Notifier White
FPTI-951 Multi-criteria photoelectric, thermal and infrared smoke detector, FlashScan, UL
listed, white.
FCO-951 Intelligent addressable combination photo and carbon monoxide detection; with
FlashScan, White
FPC-951 Intelligent multi-criteria photo/CO detector, white, UL listed
FSCO-951 Intelligent addressable carbon monoxide detector, white, UL Listed
FSV-951R High Sensitivity SMOKE DETECTOR NOTIFIER WHITE
30-3013 Explosion-Proof Smoke Detector
B501/WHITE Intelligent detector base for 951 Series Sensors, White
B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3,ANSI Temporal 4, continuous tone, marching tone,
and custom tone, White
B224BI-WH Isolator detector base, White
FlashScan Addressable Devices
ISO/X SLC Loop Isolator Module; isolates against short circuits on the SLC.
FCM/1 Addressable Control Module; Configured for one class A or Class B NAC.
FTM-1 Addressable Fire Phone Control Module
FMM/1 Addressable Monitor Module, Supervises either a Class A or Class B circuit of N.D. dry-
contact input devices.
FZM/1 Addressable 2-Wire Detector Monitor Module
FDM-1 Addressable Dual Monitor Module
FDRM-1 Dual Relay/Monitor Module.
FMM/101 Addressable Mini Module; Supervises a Class B circuit of N.D. dry-contact devises.
FMM-4-20 Addressable Module for interfacing to industry standard 4-20mA devices (used with
NFS2-3030 only)
FRM/1 Addressable Relay Module; Provides two Form-C dry contacts that switch together.
FCM-1-REL Addressable Releasing Module
SMB500-WH Surface Mount Box; for intelligent control or monitor modules, white
VEP-A00-1P-NTF Intelligent aspiration smoke detector with LED display, single pipe, covers up to
10,760 square feet.
VEP-A00-P-NTF Intelligent aspiration smoke detector with LED display, 4 pipes, covers up to 21,520
square feet.
VEP-A10-P-NTF Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to
21,520 square feet.
VEU-A00-NTF Intelligent aspiration smoke detector with LED display, 4 pipes, covers up to 69,965
square feet.
VEU-A10-NTF Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to
69,965 square feet.
VEA-040-A00-NTF Intelligent aspiration smoke detector with LED display, 40 point-addressable
detection points. Covers 36,000 square feet.
VEA-040-A10-NTF Intelligent aspiration smoke detector with LED and LCD display, 40 point-addressable
detection points. Covers 36,000 square feet.
Beam Detectors
FSB-200 Addressable Beam Detector
FSB-200S Addressable Beam Detector with remote test feature
System Sensor Detector Accessories
RA100ZRemote Led. Mounts to single gang box.
M02-09-00 Telescope handle with test magnet.
M02-04-00 Test Magnet Only.
XP-4 Extension pole, 15 ft. (three, 5ft. Poles) for use with XR2, XR2B and XR5.
XP6-R XP6 Transponder Relay Module, 6 circuits Class A or B.
XR2B Detector Installation/Removal tool kit for 800 and 355 series detectors.
DNR Intelligent Photo-electric Duct Detector
Rate Compensation Heat Detectors
302-AW-194 194 °F (90° C) vertical mount, for indoor or outdoor use.
302-EPM-194 194 °F (90° C) explosion-proof.
NBG-12 Series Pull Stations
NBG-12L Dual action lexan station, red, terminal block, Notifier Key lock.
NBG-12LOB DUAL ACTION LEXAN STATION,US
NBG-12LR PULL STA,DUAL ACTN,KL,RLSE,NOT
NBG-12LRA Abort Switch + Manual Release Switch
NBG-12LX Addressable NBG-12L Pull Station
NBG-12S SINGLE ACTION LEXAN STATION, US
Addressable manual call points
F/MCP/GLASS Addressable Manual Call point (Break-glass type)
MUS/156 Plain Callpoint Glass (Pack Of 20)
HRK Horn Only, 12 or 24 volt, Red, Wall Mount, Outdoor, Includes backbox
L-Series
P2RL HORN STROBE 2W RED WALL
SRL STROBE RED WALL
SCWL STROBE WHITE CEILING
HRL HORN RED WALL
SPRL SPEAKER RED WALL
SPWL SPEAKER WHITE WALL
SPCWL SPEAKER WHITE CEILING
SPSRL SPEAKER STROBE RED WALL
SPSCWL SPEAKER STROBE WHITE CEILING
SBBRL Wall Surface Mount Back Box, Red
LDM-32 Lamp Driver Annunciator Control Module. For use with custom graphic annunciators.
32 Points.
NFS-320E
NFS-320 Intelligent Fire Alarm Pane with one SLC loop (318 devices)Back-lit, 80
Character Display, Programming Keypad and 6.0 A Power supply, 240 VAC, Includes
door, dress panel and back box, Black
CPU2-640E Central processing unit for the NFS2-640 with integral 240V power supply, includes
CHS2-M2 Chassis.
KDM-R2 Keyboard Display Module; For CPU2-640 80-character display and QWERTY
programming keypad included.
CPU2-3030D
CPU2-3030ND
NFS2-3030 CPU with 640-character Display; Includes: CPU, 640-Character backlit LCD
display, QWERTY programming and control keypad, installation, programming and operating manuals. Supports one to 10 Signaling line circuits (up to five LCM-320 and five LEM-320).
Central processing unit for a NFS2-3030 system-no display unit; typically used for networked systems. Includes CPU, installation, programming and operating manuals.
Supports one to 10 Signaling Line Circuits (up to five LCM-320 and five LEM-320).
LCM-320 Loop Control Module. Each LCM may be expanded to two loops by adding a LEM-320. NFS2-3030 only
LEM-320 Loop Expander Module. Mounts as daughter board to LCM-320 to provide even
numbered SLC loops.
NFS2-3030/640 (only) Cabinet Mechanicals
ADP-4B Dress Plate, Annunciator, Mounts ACS annunciators and NCMs.
CHS-4L Chassis, low profile, for mounting the AA-30 or LDM.
DP-1B Dress panel blank; covers unused cabinet row(s), painted black.
DP-DISP Dress plate, display, black.
CHS-M3 Mounting Chassis, used for CPU2-3030, and NCA-2.
BP2-4 Battery Dress Panel for CAB-4 Series; for use with the NFS2-3030, NFS2-640, NCA-2,
and DVC systems.
DP-DISP2 Dress Plate used when CPU2-640 is mounted on top row.
ADP2-640 Dress Plate used when CPU2-640 is mounted on 2nd, 3rd or 4th row.
BB-25 Cabinet, mounts up to six XP6 boards or ACPS-610 (XP6 modules require a CHS-6 in
addition to BB-25).
Optional Combination Power Supply and Battery Enclosure for NFS2-3030; when
BB-100
larger batteries are required. Permits mounting of AMPS-24E power supply. Will
hold four 55 AH batteries or two 100 AH batteries.
Audio Components – Digital Voice
CA-1 Chassis, DVC, One Row
CA-2 Chassis, DVC, Two Rows, includes MIC-1; Use ADDR-XX Doors
CHS-BH1 Chassis, 12AH Battery Holder, for use with DAA
CMIC-1 Chassis with Paging Microphone with well; used with CA-1
DPA-1 Dress Plate, DVC, One Row
DPA-2B Dress Plate, DVC, Two Rows
DVC-AO Digital Voice Command, Analog Output
DVC-EM Digital Voice Command, Extended Memory
DVC-KDDigital Voice Command, Keypad
DVC-RPU Digital Voice Command, Remote Paging Station
CAB-RP Notifier Cabinet for DVC-RPU, Black
TELH-1 Firefighter’s Telephone Handset Only
RM-1 Remote Microphone
CAB-RM Remote cabinet, Grey color.
RM-1 Microphone assembly for mounting to an ADP-4 dress panel.
Digital Voice Cabinet Doors
ADDR-B4 Audio Command Door for CAB-B4, Black; Required when using CA-2
ADDR-C4 Audio Command Door for CAB-C4, Black; Required when using CA-2
ADDR-D4 Audio Command Door for CAB-D4, Black; Required when using CA-2
ACT-4 Audio Coupling Transformer. Provides isolation for DVC-AO audio system
applications w/multiple power supplies
ACT-70 Audio Coupling Transformer. Steps down 70.7 vrms audio to low level audio. Used
with DAA-5070
DAA2-5070E Digital Audio Amplifier 50W 70VRMS 240VAC
DAX-5070E 220-240 VAC Digital Audio Amplifier (50 W, 70 VRMS).
DS-FM Converts one DAX or DAA2 DAL port to multi-mode fiber
DS-SFM Converts one DAX or DAA2 DAL port to single-mode fiber
DS-AMPE DS series amplifier. 220-240VAC. Produces 125W at 25V, can be converted to a 70V,
100W amplifier with a DS-XF70V.
DS-BDA DS series backup amplifier board. 125W at 25V, can be converted to a 70V, 100W
amplifier with a DS-XF70V.
DS-DB DS series distribution board, supports one to four DS-AMPE.
DS-XF70V DS series transformer used to convert DS-AMPE, or DS-BDA to 70V, 100W.
BDA-70V Backup Digital Amplifier (70 VRMS), switch settings
for 50 and 35 W operation.
CHS-2D Chassis to mount NCA-2 in ABS-2D
BMP-1 Blank module dress plate; used to cover annunciator positions or panel positions.
Also mounts some option modules.
ABF-1B Annunciator flush box. Mounts one annunciator module.
ABF-1DB Annunciator flush box. One module. Attractive glass door & key lock.
ABF-2DB Annunciator flush box. Two modules. Attractive glass door & key lock.
ABS-2D Surface (or semi-flush) mount backbox. Used with the INA, ACS annunciators, SCS Series, and NCA-2 black.
ABS-TD Ten inch display annunciator Backbox, Surface, black. Mounts NCD and one network control module.
ONYX CAB-4 Series Cabinets
DR-A4 Door, lock & keys. Accepts 1 chassis, black.
DR-B4 Door, lock & keys. Accepts 2 chassis, black.
DR-C4 Door, lock & keys. Accepts 3 chassis, black.
DR-D4 Door, lock & keys. Accepts 4 chassis, black.
EQBB-B4 Equipment Backbox assembly, two tiers, black.
EQBB-C4 Equipment Backbox assembly, three tiers, black.
EQBB-D4 Equipment Backbox assembly, four tiers, black.
EQDR-B4 Equipment Door assembly, vented, two tiers, black.
EQDR-D4 Equipment Door assembly, vented, four tiers, black.
SBB-A4 Backbox, 1 chassis, black.
SBB-B4 Backbox, 2 chassis, black.
SBB-C4 Backbox, 3 chassis, black.
SBB-D4 Backbox, 4 chassis, black.
SBB-3 3 Gang back box for LED-10N.
BACNET-GW-3 Intelligent interface using BACnet protocol that a provides a communications links
between a Building Management System (BMS) and Fire Alarm Control Panels.
HS-NCM-MF High-Speed Network Communications Module, fiber-optic cable interface (multi-
mode).
HS-NCM-SF High-Speed Network Communications Module, fiber-optic cable interface (single-
mode)
HS-NCM-W-2 High-Speed Network Communications Module, twisted-pair wire interface
HS-NCM-WMF-2 High-Speed Network Communications Module, wire and fiber-optic cable interface
(multi-mode).
HS-NCM-WSF-2 High-Speed Network Communications Module, wire and fiber-optic cable interface
(single-mode).
MODBUS-GW ASSY,FNL,MODBUS GATEWAY
NCM-F Network Control Module – multi mode fiber; order one NCM per network node (CPU2- 640/3030,NCA-2,DVC, etc).
NCM-W Network Control Module – wire; order one NCM per network node (CPU2-
640/3030,NCA-2,DVC, etc).
NWS-3 Web-based HTML server hardware used for remote viewing of ONYXWorks
VESDA-HLI-GW Intelligent interface that provides a communication link between the NOTI-FIRE-
NET™ network and VESDA™ detectors on the VESDAnet™
VESDA™ High Level Interface used with SLC-IM and VESDA-HLI-GW to provide a
VHX-1420-HFS
communication link between the NOTI-FIRE-NET™ network and VESDA™ detectors on
the VESDAnet™
ONYX Works Network Cards
NFN-GW-PC-F NFN Gateway PC card with fiber.
NFN-GW-PC-HNW-2 High speed NFN Gateway PC card for wire
NFN-GW-PC-HNSF High speed NFN Gateway PC card for single mode fiber
ONYX Works Network Gateways
NFN-GW-PC-WNFN Gateway PC card with wire.
NFN-GW-EM-3 Intelligent gateway interface for the ONYXWorks™ fire monitoring workstation.
ONYXWORKS-Software
SW-OW-VIEW ONYXWorks Software – View Only
SW-OW-CON ONYXWorks Software – View + Control
SW-OW-CONPG ONYXWorks Software – View + Control + Paging
ONYXWORKS-Lite
ONYXWorks-Lite Graphical User Interface provides the software and hardware
OW-LITE-NW components for a Non-UL listed network application. Product includes a PCI slot
network wire card, workstation software and security key with a four node license.
PC workstation not included.
ONYXWorks-Lite Graphical User Interface provides the software and hardware
OW-LITE-NF components for a Non-UL listed network application. Product includes a PCI slot
network fiber card, workstation software and security key with a four node license.
PC workstation not included.
ONYX-LITE-4 ONYXWorks Lite Version 4 software KeyBit (Required for upgrated to Version 4)
NCD 10″ high definition color touchscreen network control display. Requires a network
communications module for networking.
NCA-2 Network Control Annunciator-2. Mounting options include annuncatior box, such as
the ABS-2DB & CHS-2D.
DP-GDIS1 ASSY,FNL,DP,NCD,FIRST ROW
DP-GDIS2 ASSY,FNL,DP,NCD,SECOND ROW
RPT-W Network Wire repeater.
Fire Fighter’s Jacks, Handsets and Storage Cabinets
FPJ/ Firefighter’s Phone Jack, India
FHS Fireman’s Telephone Hand Set.
FHSC-S Fire Phone storage cabinet, surface mount, holds 6 phones.
FHSC-R Fire Phone storage cabinet, recessed, holds 6 phones.
Notifier Warden Stations
AFAWS-BX Back box, flush or surface mount; requires a door & telephone chassis.
AFAWS-LR Door, Flush Mount, Latch Style Lock.
AFAWS-TELC Telephone Chassis with Coil Cord.
LCD Display Annunciators
LCD2-80 80 Character LCD Annunciator.
LCD-160 160 Character LCD Annunciator.
ACM-24AT
ACM-48A
ONYX series ACS annunciator; up to 96 points of annunciation with Alarm or Active LED, Trouble LED and switch per circuit. Active/Alarm LEDs can be programmed (by powered up switch selection) by point to be Red, Green or Yellow and the trouble
LED is always yellow. Expandable with one, two or three AEM-24AT’s.
ONYX series ACS annunciator; up to 96 points of annunciation with Alarm or Active
LED per circuit. Active/Alarm LEDs can be programmed (by powered up switch selection) in groups of 24 to be Red, Green or Yellow. Expandable to 96 points with
one AEM-48A.
AEM-24AT Annunciator Expander Module; 24 Alarm and Trouble LEDs, expands the ACM-24AT
to 48, 72 or 96 points.
RP-2001 Deluge and RP-2002 Agent Releasing Panels Accessories
RP-2001E Pre-action deluge control panel, 240 Volts
RP-2002E Agent release control panel, 240 Volts
PRN-7 80 column desktop printer.
FM998 FM-998, 12 Vdc, 24 Vac/Vdc, 120/250 Vac, flush wall mount.
Intelligent Panel Programming Utilities
FIRSTVISION-ENC ONYX FirstVision™ Backbox with Door
FIRSTVISION-LCD ONYX FirstVision™ User Interface software and hardware package. Includes 22″ LCD touch-screen PC with Intel® Pentium® II — 733 MHz, 512 Mbyte RAM, Onboard Ethernet, and USB ports. Package also includes one software license, and configuration software. FIRSTVISION-ENC backbox with door must be ordered
separately.
AMPS-24E Addressable power Supply, 240 VAC (NFS2-3030).
HPF24S6E 6A 24VDC F/A 220 Power Supply
ACPS-610E
Charger Power Supply – 6 or 10 amps; mounts in CAB-PS1, CAB-3/4,EQ Cabx, BB-25,
or CHS-PS1; comes with the PK-PPS programming utility. Windows® PC and USB
cable required for programming. 220 Volt
CAB-PS1 ACPS stand-alone Cabinet.
STI3150 Weather Stopper® II, surface mount.
PIBV2 Post Indicator/Butterfly Valve Supervisory Switches